Hardware Installation
Verilink Access System 2000: The Basics 4-11
Fan Alarm
To connect the fan alarm (if so equipped) to the MLS, refer to Figure
4-10 and do the following:
1. Connect one wire from the fan terminal block NC pin, to the
NCM relay terminal block NO pin.
2. Connect one wire from the fan terminal block C pin, to the
NCM relay terminal block COM pin.
3. Torque connector wire set screws to 4.5 to 8.0 inch lb (0.5 Nm
to 0.9 Nm).
Figure 4-10 Connecting the fan shelf